Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Arq. bras. cardiol ; 120(1): e20220892, 2023. tab, graf
Artigo em Português | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1420149
2.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 69(12): e20230322, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1521494

RESUMO

SUMMARY BACKGROUND: Investigation of syncope involves the use of electrophysiological study, particularly in patients with cardiac conduction disorder. There is conflicting evidence about the role of electrophysiological study in patients with Chagas disease. OBJECTIVE: The objective of this study was to evaluate the electrophysiological study findings in patients with Chagas disease and bundle branch block and/or divisional block presenting with syncope. METHODS: This is a retrospective study of patients with Chagas disease and cardiac conduction disorder who underwent electrophysiological study from 2017 to 2021 for the investigation of syncope in a tertiary hospital in São Paulo, Brazil. Those with non-interpretable ECG, known coronary artery disease, and/or other cardiomyopathies were excluded. HV interval and electrophysiological study-induced malignant ventricular arrhythmias data were analyzed. RESULTS: A total of 45 patients (60.2±11.29 years, 57.8% males) were included. The mean HV interval was 58.37 ms±10.68; 22.2% of the studied population presented an HV interval of ≥70 ms; and malignant ventricular arrhythmias were induced in 57.8% patients. The use of beta-blockers and amiodarone (p=0.002 and 0.036, respectively), NYHA functional class≥II (p=0.013), wide QRS (p=0.047), increased HV interval (p=0.02), Rassi score >6.5 (p=0.003), and reduced left ventricular ejection fraction (p=0.031) were associated with increased risk of inducible malignant ventricular arrhythmias. CONCLUSION: More than half of the patients with Chagas disease, syncope, and cardiac conduction disorder have inducible malignant ventricular arrhythmias. Prolonged HV interval was observed in only 20% of population. Wide QRS, prolonged HV, reduced ejection fraction, and higher Rassi score were associated with increased risk of malignant ventricular arrhythmias.

4.
Arq. bras. cardiol ; 115(5 supl.1): 9-9, nov. 2020.
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1128779

RESUMO

INTRODUÇÃO: As ectopias atriais podem manifestar-se de diversas formas desde a ausência de sintomas até síncope. Descrevemos um caso de bigeminismo atrial bloqueado com prolongamento do intervalo QT e consequente Torsades de Pointes. Relato de caso: Paciente do sexo feminino, 75 anos, foi admitida no serviço de pronto atendimento devido a queixa de episódios recorrentes de síncope em posição sentada após sensação inespecífica de mal-estar, dispneia e turvação visual associado a liberação esfincteriana. ECG na admissão revelou ritmo sinusal e ectopias supraventriculares frequentes, motivo pelo qual iniciou-se terapia com amiodarona. Holter de 24h demonstrou bigeminismo atrial bloqueado e prolongamento do intervalo QT seguido por episódios de Torsade de Pointes e fibrilação ventricular. Realizado implante de marcapasso provisório seguido por ablação do foco arritmogênico em região de anel triscuspídeo. A paciente evoluiu com melhora da sintomatologia e Holter de controle demonstrou ausência de arritmias.


Assuntos
Arritmias Cardíacas , Torsades de Pointes , Síncope
5.
Arq. bras. cardiol ; 115(5 supl.1): 14-14, nov. 2020. ilus
Artigo em Português | SES-SP, LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1128888

RESUMO

MÉTODOS: Trezentos e quatro pacientes consecutivos submetidos à polissonografia foram rastreados e 80 incluídos para realização de eletrocardiograma de 12 derivações e de alta resolução (ECGAR) e ecocardiograma bi e tridimensional. Foram divididos em grupos de acordo com: 1. Índice de Apneia-Hipopneia [AOS- (<15 eventos/h) e AOS+ (≥15 eventos/h)]; 2. Saturação mínima de 02 (SatMin) [>90%, 80-90% e <80%]; e 3. Tempo total de saturação de O2 <90% (T90) [<1minuto, 1-60minutos e >60minutos]. RESULTADOS: A idade média foi de 60,8±11,1 anos (60% do sexo feminino) e o IMC médio 31,95±6,5 kg/m². O grupo AOS+ apresentou menor fração de esvaziamento passivo do átrio esquerdo (FEPAE) comparado com AOS-. SatMin<80% à maior duração de onda P no ECGAR e menor strain de conduto em relação a SatMin>90%. T90 >60minutos à maior duração de onda P-ECGAR, P-máxima, P-média e P na derivação DII, menor intervalo Tinício-Tpico e menor FEPAE quando comparado ao grupo <1minuto. T90 1-60minutos à maior duração dos intervalos QT em DII e V5 e Tpico-Tfim, em relação ao grupo <1minuto. . Não houve diferenças entre os grupos quanto aos volumes atriais e demais variáveis eletrocardiográficas e funcionais. Após ajuste dos dados para idade, sexo e comorbidades, houve perda de significância estatística das variáveis funcionais. CONCLUSÃO: A presença de AOS associou-se apenas à menor FEPAE, sem alterações nas demais variáveis analisadas. O aumento no T90 associou-se ao aumento de variáveis de duração de P e de dispersão da repolarização, além da menor FEPAE. O strain de conduto foi menor e a duração da P-ECGAR maior em SatMin <80%. Os achados refletem a associação entre AOS, hipoxemia, disfunção diastólica ventricular e remodelamento atrial e a relevância da avaliação, não só da presença de AOS, mas também de índices de hipoxemia nestes pacientes.


Assuntos
Apêndice Atrial , Técnicas de Ablação , Miocárdio Ventricular não Compactado Isolado
6.
Arq. bras. cardiol ; 115(5 supl.1): 11-11, nov. 2020. ilus
Artigo em Português | SES-SP, LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1128956

RESUMO

INTRODUÇÃO: A ablação por cateter para FV surgiu como uma estratégia nos pacientes nos quais um batimento ectópico é identificado como gatilho. Descrevemos um caso de ablação de FV com sucesso, desencadeada por EV's com origem na cúspide coronariana esquerda (CCE). Relato de caso: Uma mulher de 73 anos com MCP dilatada não isquêmica (FEVE de 20%) e CDI implantado há 9 anos devido a FV induzida em EEF, foi admitida em nosso serviço por choque apropriado. ECG demonstrou EV's frequentes com morfologia de BRE e eixo inferior. Holter 24h revelou EV's monomórficas frequentes (19%) e 68 episódios de TVNS. A interrogação do dispositivo mostrou um episódio de EV desencadeando TV rápida que logo degenerou em FV. Realizada telemetria do CDI concomitante à gravação de ECG, confirmando que as ectopias espontâneas e as que desencadeavam os episódios de TV/FV eram exatamente da mesma morfologia. A paciente foi encaminhada para ablação por cateter. O mapeamento do VE foi realizado por via de acesso retroaórtica. A ativação mais precoce foi registrada na CCE com potenciais precedendo o QRS da extrassístole em 50ms. A energia de RF (potência 50W, temperatura 60°C) foi aplicada no VE em posição subcúspide (Fig.1), com eliminação imediata dos batimentos ectópicos. O Holter 24h foi repetido 2 meses após o procedimento e não mostrou arritmias ventriculares. A paciente evoluiu bem, com resolução dos sintomas e melhora da classe funcional. Discussão: O ECG desempenha um papel importante na identificação da origem das EV's. No presente caso, foram observadas EV's com morfologia de BRE e achados sugestivos de local de origem em VSVE / cúspide coronariana. As cúspides coronarianas esquerdas representam 5-8% do total de sítios focais de extrassístoles ventriculares. Este é o primeiro caso relatado de FV desencadeada por extrassístoles decorrentes da cúspide coronariana esquerda e com resolução completa dos sintomas e densidade da arritmia durante o acompanhamento. Conclusões: Descrevemos um caso de FV desencadeada por EV tratada com sucesso com ablação por RF. A raridade da FV relacionada à cúspide coronariana esquerda é o principal destaque deste caso.


Assuntos
Fibrilação Ventricular , Ablação por Cateter , Complexos Ventriculares Prematuros
7.
Rev. bras. cir. cardiovasc ; 33(4): 418-423, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-958433

RESUMO

Abstract Tetralogy of Fallot (ToF) is one of the most prevalent congenital heart disease. Its surgical corrections may haemodinamically correct a disease, but the incisions may create scars that will originate ventricular arrhythmias. Even though life threatening arrhythmias are not common, some patients present unstable ventricular tachycardia (VT) of ectopic ventricular beats triggering heart failure and symptoms. We describe the treatment of a 16-years-old woman with late ToF repair and drug refractory Implantable cardioverter defibrillator (ICD) shocks. The patient underwent successful ablation of VT using X-ray and anatomic landmarks without the use of electroanatomical mapping. We were able to reduce drugs after one month of ablation and improve quality of life and symptoms. In this paper we describe the indications and perform a brief review of the key points for successful radiofrequency catheter ablation of VT in ToF patients.


Assuntos
Humanos , Feminino , Adolescente , Tetralogia de Fallot/cirurgia , Taquicardia Ventricular/cirurgia , Ablação por Cateter/métodos , Tetralogia de Fallot/diagnóstico por imagem , Radiografia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico por imagem , Desfibriladores Implantáveis , Eletrocardiografia , Pontos de Referência Anatômicos , Ilustração Médica
8.
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-967579

RESUMO

Instabilidade elétrica atrial é um termo recentemente incorporado na prática médica para descrever o amplo espectro de arritmias atriais que se sobrepõem. Essa relação já era intuitiva entre flutter atrial e fibrilação atrial (que deu berço ao anteriormente chamado "fibrilo-flutter"), e, mais recentemente, associou taquicardias atriais e fibrilação atrial. Essa relação é de suma importância, posto que o diagnóstico de fibrilação atrial implica estratégias para prevenção de eventos embólicos. Com novos métodos de rastreio, o diagnóstico de fibrilação atrial se mostrou mais frequente (monitorização prolongada, monitores implantáveis, telemetria de marcapassos). A presença de extrassistolia atrial e taquicardia atrial se torna um desafio: apesar da relação intuitiva de maior risco para fibrilação atrial e eventos cerebrovasculares, a evidência científica para tal se tornou mais robusta recentemente. Este artigo tem a intenção de agregar a evidência de melhor qualidade disponível para facilitar a seleção da estratégia adequada ante um paciente portador de taquicardia e extrassistolia atrial e avaliar adequadamente seu risco


Atrial electrical instability is a recently incorporated term in medical practice to describe the broad spectrum of overlapping atrial arrhythmias. This relationship was already intuitive between atrial flutter and atrial fibrillation (which gave birth to the so-called "fibril-flutter"), and has more recently been related to atrial tachycardias and atrial fibrillation. This relationship is extremely important, since the diagnosis of atrial fibrillation implies in strategies to prevent embolic events. With new screening methods, the diagnosis of atrial fibrillation has become more frequent (prolonged monitoring, implantable monitors, pacemaker telemetry). The presence of atrial extrasystoles and atrial tachycardia is a challenge: despite the intuitive relationship of higher risk for atrial fibrillation and cerebrovascular events, the scientific evidence became more robust recently. This article intends to aggregate the best quality evidence available to facilitate the choice of an appropriate strategy for a patient with tachycardia and atrial extrasystoles and to adequately assess their risk


Assuntos
Humanos , Masculino , Feminino , Arritmias Cardíacas/diagnóstico , Fibrilação Atrial , Taquicardia Atrial Ectópica/diagnóstico , Nó Atrioventricular , Fatores de Risco , Complexos Atriais Prematuros/etiologia , Eletrocardiografia/métodos , Coração , Átrios do Coração , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico
9.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 31(2)abr.-jun. 2018. ilus, tab
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-914188

RESUMO

A taquicardia por reentrada ramo a ramo, apesar de ter sido descrita há cerca de 30 anos, é entidade por vezes desconhecida de muitos cardiologistas e, por vezes, não identificada por eletrofisiologistas. Provavelmente subdiagnosticada, em especial nos portadores de cardiomiopatia dilatada, essa entidade acomete pacientes com lesão do sistema elétrico infra-hissiano. O reconhecimento dessa arritmia é importante para poder oferecer tratamento curativo, diminuir a necessidade de antiarrítmicos e minimizar terapias apropriadas após um implante de cardiodesfibrilador implantável


Although the bundle-branch reentrant tachycardia was described about 30 years ago, it is unknown to many cardiologists, and at times it is not identified by electrophysiologists. Probably underdiagnosed, especially in patients with dilated cardiomyopathy, this entity affects patients with lesion of the infra-His system. Identifying this arrhythmia is important to enable curative treatment, decrease the need for antiarrhythmics and minimize appropriate therapies after the implant of an implantable cardiac defibrillator


Assuntos
Humanos , Feminino , Idoso , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Bloqueio de Ramo/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Diagnóstico por Imagem/métodos , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/etiologia , Desfibriladores Implantáveis , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Eletrofisiologia/métodos , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca , Ventrículos do Coração
10.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(2): f:55-l:57, abr.-jun. 2017. ilus
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-848051

RESUMO

Monitores de eventos implantáveis estão cada vez mais presentes em nossa realidade. Este relato tem como foco o registro eletrocardiográ- fico obtido por monitor de eventos implantável durante ressonância magnética de paciente com síncope de repetição. O registro demonstra traçado interpretado erroneamente como taquicardia ventricular. O reconhecimento de interferências deve ser parte do treinamento do médico que atende e avalia dispositivos implantáveis


Implantable loop recorders are increasingly more present in our reality. This report is focused on the electrocardiographic recording obtained by implantable loop monitor during magnetic resonance imaging in patients with repeated syncope. The recording shows a tracing misinterpreted as ventricular tachycardia. Identifying interferences must be part of the training of attending physicians who sees patients and evaluates implantable devices


Assuntos
Humanos , Masculino , Idoso , Marca-Passo Artificial , Desfibriladores Implantáveis/tendências , Radiação Eletromagnética , Síncope/diagnóstico , Ecocardiografia/métodos , Espectroscopia de Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico , Eletrodos Implantados/tendências , Frequência Cardíaca
11.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(1): 3-8, jan.-mar. 2017. ilus, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-837227

RESUMO

Introdução: Este trabalho teve por objetivos identificar as características comuns aos geradores e classificá-los no menor número possível de grupos para facilitar a identificação radiológica, e, também, identificar características que permitam diferenciar geradores DF1 de DF4. Método: A amostragem foi composta por 62 imagens de geradores de dispositivos implantáveis bem como de cabos-eletrodos comercialmente disponíveis no Brasil de 2008 até o presente momento das empresas Biotronik, Medtronic, St. Jude Medical e Boston Scientific. As imagens consideradas com qualidade adequada de cada modelo de dispositivo implantável foram selecionadas em busca de características comuns a cada fabricante. Resultados: A revisão criteriosa das características de cada fabricante e modelo possibilitou divisar claramente oito categorias, com características únicas de cada fabricante para estimuladores (grupo 1) e cardiodesfibriladores (grupo 2). Um algoritmo de identificação foi desenvolvido, a partir das características mais facilmente identificáveis de cada grupo. Conclusão: A identificação radiológica dos dispositivos implantáveis é possível e confiável. Os cabos-eletrodos de mesma função (choque ou estimulação) não puderam ser diferenciados em relação ao fabricante, mas algumas características das conexões de cabos-eletrodos de choque podem diferenciar a conexão DF1 de DF4, bem como mono coil de duplo coil


Background: This study is aimed at identifying common characteristics of generators and classify them into the lowest possible number of groups to facilitate X-ray identification as well as to identify characteristics to differentiate DF1 and DF4 generators. Method: The sample included 62 images of implantable device generators and leads available in the Brazilian market from 2008 to the present moment manufactured by Biotronik, Medtronic, St. Jude Medical and Boston Scientific. Good quality images from each implantable device model were chosen to help identify common characteristics of each manufacturer. Results: A careful review of manufacturer's characteristics and model enabled a clear division into eight categories with each manufacturer's unique characteristics for pacers (group 1) and cardiac defibrillators (group 2). An identification algorhythm was developed based on the most easily identifiable characteristics of each group. Conclusion: X-ray identification of implantable devices is possible and reliable. Leads with the same function (shock or pacing) were not differentiated by manufacturer, but some shock lead connection characteristics may differentiate DF1 from DF4 connections, as well monocoil from double coil


Assuntos
Humanos , Raios X , Radiografia/métodos , Desfibriladores Implantáveis/tendências , Marca-Passo Artificial , Eletrodos/normas , Dispositivos de Terapia de Ressincronização Cardíaca/tendências , Indústrias/normas
12.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(1): 16-23, jan.-mar.2016. ilus, tab
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-788820

RESUMO

Síndrome do QT longo congênito é uma síndrome arrítmica hereditária caracterizada por prolongamento do intervalo QT no eletrocardiograma de 12 derivações, torsades de pointes e maior chance de morte súbita cardíaca. A síndrome do QT longo congênito possui padrão autossômico dominante (síndrome de Romano-Ward), bem como padrão autossômico recessivo raro (síndrome de Jervell e Lange-Nielsen). Desde 1957, quando Jervell e Lange-Nielsen relataram os primeiros casos de síndrome do QT longo congênito familiarcom surdez congênita, a compreensão dos mecanismos genéticos e eletrofisiológicos dessa afecção melhorousignificativamente os métodos diagnósticos e os tratamentos. No entanto, tornou-se evidente que a síndrome do QT longo congênito nem sempre pode ser explicada pela mutação de um único gene. Esta revisão teve por objetivo resumir as características da síndrome do QT longo congênito (principalmente LQT1, LQT2 e LQT3) e descrever brevemente os mais recentes avanços no diagnóstico clínico e no tratamento da afecção...


Congenital long QT syndrome is an inherited arrhythmia syndrome characterized by a prolonged QT interval on the 12-lead electrocardiogram, torsades de pointes and a higher chance of sudden cardiac death. Congenital long QT syndrome includes an autosomal dominant pattern (Romano-Ward syndrome) as well as a rare autosomal recessive pattern (Jervell and Lange-Nielsen syndrome). Since 1957 when Jervell and Lange Nielsen reported the first familial long QT syndrome with congenital deafness, the understanding of genetic and electrophysiological mechanisms of long QT syndrome has significantly improved diagnostic methods and treatments. However, is clear that long QT syndrome cannot always be explained by a single gene mutation. This review is aimed at summarizing the characteristics of congenital long QT syndrome (mainly LQT1, LQT2 e LQT3) and briefly describe the most recent advances in long QT syndrome clinical diagnostics and treatment...


Assuntos
Humanos , Cardiopatias Congênitas , Morte Súbita Cardíaca/prevenção & controle , Síndrome do QT Longo/congênito , Antagonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Eletrocardiografia/métodos , Síncope/complicações
13.
ABC., imagem cardiovasc ; 29(1): 25-27, jan.-mar.2016. ilus
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-777620

RESUMO

A fibrilação atrial (FA) é a arritmia cardíaca sustentadamais frequente na prática clínica. Dados epidemiológicosdemonstram que a FA está associada a morbidadee a mortalidade expressivas, acarretando custosmédico-hospitalares elevados.1 O desalento geradopelo impacto modesto dos agentes antiarrítmicos nahistória natural da FA motivou o desenvolvimento demétodos não farmacológicos, visando o tratamentocurativo dessa arritmia. Nesse contexto, na últimadécada, a ablação por cateter com técnicas percutâneasevoluiu consideravelmente, consolidando-se comoopção terapêutica em pacientes selecionados com FA.2Métodos de imagem, tais como ecocardiografia intracardíacae mapeamento eletroanatômico, têm sido cada vez maisincorporados, com a finalidade de aumentar a eficiência ea segurança do método. A eficácia da ablação vem sendodiscutida nos últimos tempos buscando-se evidenciarfatores que contribuem para as taxas de recorrência daFA. A falha do procedimento é muitas vezes atribuídaà retomada da condução entre as veias pulmonares e oátrio esquerdo em razão da ablação incompleta dos focosectópicos.3...


Assuntos
Humanos , Masculino , Adulto , Ablação por Cateter/métodos , Espectroscopia de Ressonância Magnética/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Veias Pulmonares , Arritmias Cardíacas , Ecocardiografia/métodos , Resultado do Tratamento , Átrios do Coração
14.
Einstein (Säo Paulo) ; 12(3): 295-299, Jul-Sep/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-723928

RESUMO

Objective To correlate arrhythmic symptoms with the presence of significant arrhythmias through the external event monitoring (web-loop). Methods Between January and December 2011, the web-loop was connected to 112 patients (46% of them were women, mean age 52±21 years old). Specific arrhythmic symptoms were defined as palpitations, pre-syncope and syncope observed during the monitoring. Supraventricular tachycardia, atrial flutter or fibrillation, ventricular tachycardia, pauses greater than 2 seconds or advanced atrioventricular block were classified as significant arrhythmia. The association between symptoms and significant arrhythmias were analyzed. Results The web-loop recorded arrhythmic symptoms in 74 (66%) patients. Of these, in only 14 (19%) patients the association between symptoms and significant cardiac arrhythmia was detected. Moreover, significant arrhythmia was found in 11 (9.8%) asymptomatic patients. There was no association between presence of major symptoms and significant cardiac arrhythmia (OR=0.57, CI95%: 0.21-1.57; p=0.23). Conclusion We found no association between major symptoms and significant cardiac arrhythmia in patients submitted to event recorder monitoring. Event loop recorder was useful to elucidate cases of palpitations and syncope in symptomatic patients. .


Objetivo Correlacionar sintomas arrítmicos com a presença de arritmias significativas por meio do monitor de eventos externo (web-loop). Métodos Entre janeiro e dezembro de 2011, o web-loop foi instalado em 112 pacientes (46% mulheres, 52±21 anos). Sintomas específicos foram definidos como palpitação, pré-síncope e síncope, presentes durante a monitorização. Arritmia significativa foi definida como taquicardia paroxística supraventricular, flutter e fibrilação atrial, taquicardia ventricular, pausas superiores a 2 segundos ou bloqueio atrioventricular avançado. A associação entre presença de sintomas e arritmias significativas foi avaliada. Resultados O monitor de eventos registrou sintomas específicos em 74 (66%) pacientes, entretanto a associação entre sintomas específicos e arritmia significativa foi observada em apenas 14 (19%) deles. Em 11 pacientes (9,8%), foi detectada arritmia significativa na ausência de sintomas. Não houve associação entre a presença de sintomas e a detecção de arritmia significativa (OR=0,57, IC95%: 0,21-1,57; p=0,23). Conclusão Em pacientes monitorizados pelo web-loop, não houve associação entre a presença de sintomas específicos e a detecção de arritmias significativas. O monitor de eventos pode ter importância na elucidação de sintomas de palpitações e síncope dos pacientes. .


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Síncope/diagnóstico , Síncope/fisiopatologia , Arritmias Cardíacas/etiologia , Distribuição de Qui-Quadrado , Eletrocardiografia Ambulatorial/métodos , Reprodutibilidade dos Testes , Fatores de Tempo
15.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(2): 77-84, abr.-jun.2014.
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-727486

RESUMO

Introdução: A aplicação do eletrocardiograma de 12 derivações para localizar a via acessória na síndrome de Wolff-Parkinson-White é útil para o planejamento terapêutico invasivo. Este estudo teve como objetivo definir as características eletrocardiográficas preditoras da localização médio-septal e relatar os resultados obtidos em pacientes submetidos a ablação por radiofrequência. Método: Estudo retrospectivo e longitudinal, analisando características eletrocardiográficas pré e pós-ablação e informações referentes aos resultados após o procedimento. Resultados: Integraram o estudo 91 pacientes, 11 dos quais apresentaram via acessória com localização médio-septal. As características eletrocardiográficas preditoras da via médio-septal foram: padrão de bloqueio de ramo esquerdo em V1 (odds ratio = 50; P = 0,008), onda delta positiva em D3 (odds ratio = 20,8; P = 0,04) e complexo QRS não positivo em V2 (odds ratio = 15,2; P = 0,003). Nessa sequência, os achados foram combinados na forma de algoritmo para predizer a localização da via médio-septal, com acurácia de 92,3%, sensibilidade de 90,4%, especificidade de 92,5% e valor preditivo negativo de 87,9%. O sucesso foi menor na via médio-septal que nas demais vias (45,5% e 87,5%, respectivamente; P = 0,001). Com relação às complicações, não houve diferença estatística de indução de bloqueio atrioventricular entre a via médio-septal e as demais vias. Conclusão: Os achados eletrocardiográficos foram capazes de predizer a via médio-septal com boa acurácia. Houve mais insucesso na via médio-septal e taxas similares de complicações nas outras vias.


Background:The application of 12-lead electrocardiogram to locate the accessory pathway in Wolff-Parkinson-White syndrome is useful invasive therapy planning. The aim of this study is to define electrocardiographiccharacteristics that predict the midseptal accessory pathway location and report the results obtained in patientsundergoing radiofrequency ablation.Method:Retrospective, longitudinal study analyzing electrocardiogramfeatures pre and post-ablation and information related to post-procedure results.Results:Ninety-one patientswere included, of which 11 had midseptal accessory pathway location. These electrocardiographic characteristicswere predictive of midseptal accessory pathway: left bundle branch block pattern in V1 (odds ratio = 50; P = 0.008),positive delta wave in D3 (odds ratio = 20.8; P = 0.04) and QRS complex non-positive in V2 (odds ratio = 15.2;P = 0.003). Subsequently, the findings were combined as an algorithm to predict the location of the midseptalaccessory pathway, with an accuracy of 92.3%, sensitivity of 90.4%, specificity of 92.5% and negative predictivevalue of 87.9%. Success was lower in the midseptal pathway than in other pathways (45.5% and 87.5% respectively;P = 0.001). With regard to complications, there was no statistical difference in induction of atrioventricular blockbetween midseptal pathway and the other pathways.Conclusion:The electrocardiographic findings were able to predict the midseptal accessory pathway with good accuracy. There were more failures in the midseptal accessorypathway and similar complication rates for the other pathways.


Assuntos
Humanos , Masculino , Adulto , Ablação por Cateter/métodos , Bloqueio Atrioventricular/diagnóstico , Síndrome de Wolff-Parkinson-White/complicações , Eletrocardiografia/métodos , Estudos Retrospectivos , Prontuários Médicos/estatística & dados numéricos
16.
Einstein (Säo Paulo) ; 11(3): 291-295, jul.-set. 2013. tab
Artigo em Português | LILACS | ID: lil-688631

RESUMO

OBJETIVO: A doença de Chagas constitui importante problema de saúde pública global devido às mudanças nos padrões migratórios. O estudo eletrofisiológico é usualmente indicado na avaliação da função do nó sinusal, condução pelo nó atrioventricular e sistema His-Purkinje e mecanismos das arritmias. O objetivo deste estudo foi descrever as características do estudo eletrofisiológico em pacientes com doença de Chagas. MÉTODOS: Estudo retrospectivo e descritivo de 115 pacientes consecutivos com doença de Chagas submetidos ao estudo eletrofisiológico nos últimos 3 anos em centro terciário no Brasil. Características basais, eletrocardiográficas, ecocardiográficas e de Holter de 24 horas foram avaliadas e correlacionadas aos achados do estudo eletrofisiológico. RESULTADOS: Os tempos corrigidos de recuperação do nó sinusal e condução sinoatrial foram anormais em 6,9% e 26,1% dos pacientes, respectivamente. Apresentaram condução atrioventricular anormal 37 (32,2%) pacientes. A condução intraventricular mostrou-se alterada em 39 (33,9%) pacientes. Em aproximadamente 48%, houve indução de arritmias ventriculares sustentadas, sendo a maioria monomórfica (83,6%). A morfologia de bloqueio de ramo direito foi a mais comumente observada (52,7%). Dentre as arritmias, 51% associaram-se a sintomas/instabilidade hemodinâmica, 60% necessitaram de cardioversão elétrica e 27,3% de estimulação rápida. O sítio de origem mais comum foi a parede inferosseptal do ventrículo esquerdo (18,2%), seguido pela parede posterobasal (11%). Pacientes com fração de ejeção<40% tiveram risco 1,94 vez maior de indução de arritmias ventriculares comparados àqueles com fração de ejeção>60% (OR: 1,94; IC95%: 1,12-3,38; p=0,01). A presença de arritmias ventriculares complexas no Holter não foi preditiva de indução de arritmias ventriculares. CONCLUSÕES: Chagásicos com fração de ejeção baixa apresentam maior risco de arritmias ventriculares induzidas. Disfunção do nó sinusal e anormalidades da condução...


OBJECTIVE: Chagas disease has become a global problem due to changing migration patterns. An electrophysiological study is generally indicated for assessing sinus node function, conduction through the atrioventricular node and His-Purkinje system, in addition to evaluating the mechanisms of arrhythmia. The aim of this study was to describe the characteristics of electrophysiological study findings in patients with Chagas disease. METHODS: A retrospective descriptive study of 115 consecutive patients with Chagas disease undergoing an electrophysiological study over the last three years in a tertiary hospital in Brazil. Baseline characteristics, electrocardiogram, echocardiogram, and 24-hour Holter monitoring findings were recorded and correlated with the electrophysiological study findings. RESULTS: The corrected sinus node recovery time and sinoatrial conduction time were abnormal in 6.9% and 26.1% of patients, respectively. Thirty-seven (32.2%) had abnormal atrioventricular conduction. Intraventricular conduction was abnormal in 39 (33.9%). Approximately 48% had induced sustained ventricular arrhythmias, most of which were monomorphic (83.6%). Right bundle branch block was the most common morphology (52.7%). Fifty-one percent were associated with symptoms/hemodynamic instability, 60% required electrical cardioversion, and 27.3% needed overdrive suppression. The most common site of origin was the left ventricular inferoseptal wall (18.2%), followed by the left ventricular posterobasal wall (11%). Patients with an ejection fraction<40% had a 1.94-fold increased risk of ventricular arrhythmias compared to those with an ejection fraction>60% (OR: 1.94; 95%CI: 1.12-3.38; p=0.01). The presence of complex ventricular arrhythmias on Holter did not predict inducible ventricular arrhythmias. CONCLUSIONS: Chagas patients with a low ejection fraction have an increased risk of inducible ventricular arrhythmias. Sinus node dysfunction, and atrioventricular node...


Assuntos
Arritmias Cardíacas , Doença de Chagas , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA